DiversiTech, 7-CRNR35, Dual Element Fuse, 35 A, 250 V, 200,000 A
36 Available At All US Supply Locations
Contractor-Grade Overcurrent Protection – DiversiTech® 7-CRNR35 RK5 Dual Element Time Delay Fuse
The DiversiTech® 7-CRNR35 is a dual-element time delay fuse designed to safeguard HVAC and motor-driven systems from short circuits and prolonged overloads. With a Class RK5 classification and a 200,000 A interrupting capacity, this fuse supports high fault current environments while minimizing nuisance tripping during inrush conditions.
Engineered for System Longevity and Compliance
This 35A, 250VAC-rated fuse is purpose-built for demanding electrical applications such as air conditioning and refrigeration systems, motor control circuits, and other inductive loads. The dual-element design delivers superior protection during motor startup while preserving system uptime.
Key Technical Advantages
- Amperage Rating: 35 A
- Voltage Rating: 250 VAC
- Interrupting Rating: 200,000 A RMS Symmetrical
- Construction: Dual element, time delay
- Class: RK5 per UL 248-12
Performance Features
- ✅ Dual Element Time Delay – Allows temporary overloads typical of motor startups without compromising protection.
- ✅ RK5 Certification – Meets the performance requirements for industrial fusing applications requiring short-circuit protection.
- ✅ High Interrupt Capacity – Rated for 200kA to safely isolate high fault currents.
- ✅ Consistent Arc-Quenching – Reduces potential damage to downstream components in fault scenarios.
Installation Considerations
Installation of the 7-CRNR35 should be completed by a qualified electrician or HVAC technician. Ensure compatibility with fuse holders rated for Class RK5 fuses and verify circuit parameters against nameplate data. Always de-energize equipment prior to replacement.
Contractor Use Cases
For licensed HVAC and electrical contractors: The 7-CRNR35 supports reliable operation across a range of motor-driven loads, with added protection during startup. It’s a cost-effective solution that reduces callbacks due to unnecessary tripping and minimizes equipment exposure to short circuit damage.
Compliance and Standards
- UL Listed: UL 248-12, Class RK5
- CSA Certified: CSA C22.2 No. 248.12
Professional Summary
The DiversiTech® 7-CRNR35 Dual Element Time Delay Fuse is an essential protective component for high-load HVAC and motor applications. It ensures coordinated circuit protection, minimizes service disruptions, and meets the demands of professional environments requiring robust overcurrent mitigation.
Contractor-Grade Overcurrent Protection – DiversiTech® 7-CRNR35 RK5 Dual Element Time Delay Fuse
The DiversiTech® 7-CRNR35 is a dual-element time delay fuse designed to safeguard HVAC and motor-driven systems from short circuits and prolonged overloads. With a Class RK5 classification and a 200,000 A interrupting capacity, this fuse supports high fault current environments while minimizing nuisance tripping during inrush conditions.
Engineered for System Longevity and Compliance
This 35A, 250VAC-rated fuse is purpose-built for demanding electrical applications such as air conditioning and refrigeration systems, motor control circuits, and other inductive loads. The dual-element design delivers superior protection during motor startup while preserving system uptime.
Key Technical Advantages
- Amperage Rating: 35 A
- Voltage Rating: 250 VAC
- Interrupting Rating: 200,000 A RMS Symmetrical
- Construction: Dual element, time delay
- Class: RK5 per UL 248-12
Performance Features
- ✅ Dual Element Time Delay – Allows temporary overloads typical of motor startups without compromising protection.
- ✅ RK5 Certification – Meets the performance requirements for industrial fusing applications requiring short-circuit protection.
- ✅ High Interrupt Capacity – Rated for 200kA to safely isolate high fault currents.
- ✅ Consistent Arc-Quenching – Reduces potential damage to downstream components in fault scenarios.
Installation Considerations
Installation of the 7-CRNR35 should be completed by a qualified electrician or HVAC technician. Ensure compatibility with fuse holders rated for Class RK5 fuses and verify circuit parameters against nameplate data. Always de-energize equipment prior to replacement.
Contractor Use Cases
For licensed HVAC and electrical contractors: The 7-CRNR35 supports reliable operation across a range of motor-driven loads, with added protection during startup. It’s a cost-effective solution that reduces callbacks due to unnecessary tripping and minimizes equipment exposure to short circuit damage.
Compliance and Standards
- UL Listed: UL 248-12, Class RK5
- CSA Certified: CSA C22.2 No. 248.12
Professional Summary
The DiversiTech® 7-CRNR35 Dual Element Time Delay Fuse is an essential protective component for high-load HVAC and motor applications. It ensures coordinated circuit protection, minimizes service disruptions, and meets the demands of professional environments requiring robust overcurrent mitigation.
Specifications
| Weight | 0.200000 |
|---|---|
| Length (inches) | 0.75 |
| Width (inches) | 0.75 |
| Height (inches) | 3 |
| Item Type | Fuse |
| Brand | DiversiTech |
| Interrupt Rating | 200,000 A |
| Manufacturer | DiversiTech Corporation |
| MPN | 7-CRNR35 |
| Amperage Rating | 35 A |
| Item Returns | This item can be returned |