DiversiTech, 7-CRNR35, Dual Element Fuse, 35 A, 250 V, 200,000 A

MPN
7-CRNR35
SKU
1896269
In stock
1 Available At My Branch
36 Available At All US Supply Locations

Contractor-Grade Overcurrent Protection – DiversiTech® 7-CRNR35 RK5 Dual Element Time Delay Fuse

The DiversiTech® 7-CRNR35 is a dual-element time delay fuse designed to safeguard HVAC and motor-driven systems from short circuits and prolonged overloads. With a Class RK5 classification and a 200,000 A interrupting capacity, this fuse supports high fault current environments while minimizing nuisance tripping during inrush conditions.

Engineered for System Longevity and Compliance

This 35A, 250VAC-rated fuse is purpose-built for demanding electrical applications such as air conditioning and refrigeration systems, motor control circuits, and other inductive loads. The dual-element design delivers superior protection during motor startup while preserving system uptime.

Key Technical Advantages

  • Amperage Rating: 35 A
  • Voltage Rating: 250 VAC
  • Interrupting Rating: 200,000 A RMS Symmetrical
  • Construction: Dual element, time delay
  • Class: RK5 per UL 248-12

Performance Features

  • Dual Element Time Delay – Allows temporary overloads typical of motor startups without compromising protection.
  • RK5 Certification – Meets the performance requirements for industrial fusing applications requiring short-circuit protection.
  • High Interrupt Capacity – Rated for 200kA to safely isolate high fault currents.
  • Consistent Arc-Quenching – Reduces potential damage to downstream components in fault scenarios.

Installation Considerations

Installation of the 7-CRNR35 should be completed by a qualified electrician or HVAC technician. Ensure compatibility with fuse holders rated for Class RK5 fuses and verify circuit parameters against nameplate data. Always de-energize equipment prior to replacement.

Contractor Use Cases

For licensed HVAC and electrical contractors: The 7-CRNR35 supports reliable operation across a range of motor-driven loads, with added protection during startup. It’s a cost-effective solution that reduces callbacks due to unnecessary tripping and minimizes equipment exposure to short circuit damage.

Compliance and Standards

  • UL Listed: UL 248-12, Class RK5
  • CSA Certified: CSA C22.2 No. 248.12

Professional Summary

The DiversiTech® 7-CRNR35 Dual Element Time Delay Fuse is an essential protective component for high-load HVAC and motor applications. It ensures coordinated circuit protection, minimizes service disruptions, and meets the demands of professional environments requiring robust overcurrent mitigation.

Contractor-Grade Overcurrent Protection – DiversiTech® 7-CRNR35 RK5 Dual Element Time Delay Fuse

The DiversiTech® 7-CRNR35 is a dual-element time delay fuse designed to safeguard HVAC and motor-driven systems from short circuits and prolonged overloads. With a Class RK5 classification and a 200,000 A interrupting capacity, this fuse supports high fault current environments while minimizing nuisance tripping during inrush conditions.

Engineered for System Longevity and Compliance

This 35A, 250VAC-rated fuse is purpose-built for demanding electrical applications such as air conditioning and refrigeration systems, motor control circuits, and other inductive loads. The dual-element design delivers superior protection during motor startup while preserving system uptime.

Key Technical Advantages

  • Amperage Rating: 35 A
  • Voltage Rating: 250 VAC
  • Interrupting Rating: 200,000 A RMS Symmetrical
  • Construction: Dual element, time delay
  • Class: RK5 per UL 248-12

Performance Features

  • Dual Element Time Delay – Allows temporary overloads typical of motor startups without compromising protection.
  • RK5 Certification – Meets the performance requirements for industrial fusing applications requiring short-circuit protection.
  • High Interrupt Capacity – Rated for 200kA to safely isolate high fault currents.
  • Consistent Arc-Quenching – Reduces potential damage to downstream components in fault scenarios.

Installation Considerations

Installation of the 7-CRNR35 should be completed by a qualified electrician or HVAC technician. Ensure compatibility with fuse holders rated for Class RK5 fuses and verify circuit parameters against nameplate data. Always de-energize equipment prior to replacement.

Contractor Use Cases

For licensed HVAC and electrical contractors: The 7-CRNR35 supports reliable operation across a range of motor-driven loads, with added protection during startup. It’s a cost-effective solution that reduces callbacks due to unnecessary tripping and minimizes equipment exposure to short circuit damage.

Compliance and Standards

  • UL Listed: UL 248-12, Class RK5
  • CSA Certified: CSA C22.2 No. 248.12

Professional Summary

The DiversiTech® 7-CRNR35 Dual Element Time Delay Fuse is an essential protective component for high-load HVAC and motor applications. It ensures coordinated circuit protection, minimizes service disruptions, and meets the demands of professional environments requiring robust overcurrent mitigation.

Specifications

Specifications
Weight 0.200000
Length (inches) 0.75
Width (inches) 0.75
Height (inches) 3
Item Type Fuse
Brand DiversiTech
Interrupt Rating 200,000 A
Manufacturer DiversiTech Corporation
MPN 7-CRNR35
Amperage Rating 35 A
Item Returns This item can be returned